Wrap the blood pressure cuff around the upper arm.

00:00:10.781 --> 00:00:13.411
Place the stethoscope earpieces in your ears.

00:00:13.828 --> 00:00:18.307
Ensure the earpieces are facing forward.

00:00:18.708 --> 00:00:23.213
Place the diaphragm over the brachial artery.

00:00:23.672 --> 00:00:31.167
Inflate the cuff to 30 mmHg higher than the estimated systolic pressure.

00:00:31.562 --> 00:00:35.698
Slowly reduce the pressure in the cuff (around 2–3 mmHg per second).

00:00:36.253 --> 00:00:41.250
Listen through the stethoscope for Korotkoff sounds.

00:00:41.702 --> 00:00:44.922
At the systolic pressure, sharp, tapping sounds are first heard.

00:00:45.452 --> 00:00:50.260
At the diastolic pressure the sounds disappear.

00:00:50.701 --> 00:00:58.695
Completely deflate the cuff once diastolic pressure is determined.