Obtain and wear gloves throughout the procedure.

00:00:08.539 --> 00:00:20.234
Connect one end of the rubber tube to the syringe
and the other end to the glass pipette.

00:00:20.351 --> 00:00:27.928
Slowly pull the plunger to collect 0.5 parts of semen solution.
The solution is colored blue for demonstration purposes.

00:00:28.008 --> 00:00:30.664
Wipe off any excess solution from the outside of the pipette.

00:00:30.781 --> 00:00:35.234
Fill the pipette with dilution solution up to the 11 part mark.
The dilution solution is colored pink for demonstration purposes.

00:00:35.313 --> 00:00:41.649
To mix the solution, hold the pipette horizontally and use your fingers to slowly roll the pipette.

00:00:41.758 --> 00:00:47.343
Roll the pipette until the two solutions are mixed thoroughly.

00:00:47.663 --> 00:00:56.144
Discard the first few drops of mixed solution onto a paper towel.

00:00:56.272 --> 00:01:01.584
Place the Improved Neubauer Chamber on a flat surface and place a coverslip on top.

00:01:01.679 --> 00:01:03.320
Place the end of the pipette next to the coverslip above the central platform.

00:01:03.359 --> 00:01:05.859
Slowly release the plunger to allow a droplet to form.

00:01:05.859 --> 00:01:11.679
The droplet will enter the chamber through capillary action
when it comes into contact with the coverslip.

00:01:11.719 --> 00:01:17.578
Only one droplet should fill the chamber.
Take care not to add extra solution.